MAINTENANCE SECTION 5 Page 19 5.6. AIR CLEANING SYSTEM 3. Mask the entire perforated metal outside diameter of safety element (smaller) with the duct tape and reinstall. Sealing must be airtight. Connect regulated compressed air supply to one of existing connecting ports on air intake manifold. Connect pressure gauge to other connecting port on intake manifold or to warning light switch. 4. Check if underpressure of 0.14 – 0.21 kG/cm 2 has been obtained by reading the pressure. If improper pressure is seen, adjust pressure to 0.14 – 0.21 kG/cm 2 by cranking the engine crankshaft to a position where minimum leakage occurs past engine valves. 5.
Coat the following areas with soap solution and check for leaks. Leaks will cause air bubbles to form. a) air cleaner body surface around the outlet pipe to app. the outside diameter of safety element b) air cleaner outlet to turbocharger inlet hose to air cleaner body junction c) orifice and tubing from the air cleaner d) all clamped hose and gasket connections between air cleaner outlet and intake manifold. This includes connections at turbocharger e) surface of all air induction piping and hoses air cleaner and air intake manifold including the manifold gasket area 6. No leakage is permitted between air cleaner and intake manifold (the entire air induction system).
Test frequency Air intake system leakproof tests must be performed after each Disassembly of intake system or if necessary (leaks or loosens clamps). 5.7. BELTS General WARNING! Keep clear of fan and fan belts when the engine is running. Rotating fan and belt contact can cause injury. Fig. 5.4. Belt Inspection DRESSTA TD-40C