Komatsu — Bucket Level Indicator

OPERATION Adjusting Bucket Positioner 1. Lower the bucket to the ground; set to the desired digging angle. 2. Return the bucket control lever to the HOLD position; lock the work equipment control lever; and stop the engine. 3. Loosen two bolts (1) and adjust mounting bracket (4) of the proximity switch so that the rear tip of angle (2) is in line with the center of the sensing surface of the proximity switch (3). Tighten the bolts to hold the bracket in position. 4. Loosen two nuts (5) and adjust to make a clearance of 3 to 5 mm (0.118 to 0.197 in) between bar (2) and the sensing surface of proximity switch (3). Tighten the nuts to hold in position. Tightening torque:. . . . . . . . . . .

.(17.2 ±2.5 N•m (12.69 ±1.84 lbf ft) 5. After adjusting, start the engine and raise the lift arm. 6. Operate the bucket control lever to the DUMP position, then operate it to the TILT BACK position and check that the lever is automatically returned to the HOLD position when the bucket reaches the desired digging angle. Bucket Level Indicator Level indicators (A) and (B) are located at the rear of the bucket. They check the bucket angle during operation. A: Parallel with cutting edge B: 90° to cutting edge 2-92 WA500-3LK