Komatsu — Installing the Bucket

OPERATION 5. Pull out and remove bucket hinge pin (4) on both sides of the bucket. 6. Disconnect the lift arm and bucket. Installing the Bucket Read the safety instructions; see “Removing the Bucket” on page 2-93. Remark Before installing the bucket, remove all grease, mud, or sand and clean the pin, pin hole, and area around the boss. (If there is any rust or dirt on the inside surface of the pin hole, use sandpaper and remove it carefully.) After cleaning, coat the pin and inside surface of the pin hole with fresh grease. 1. Set cord ring (2) on top of lift arm boss (1). 2. Coat dust seal lip portion (3) with grease. 3. Align the left and right bucket pin holes. 2-94 WA500-3LK