When Required MAINTENANCE Check, Clean, Replace Air Cleaner Element If inspection, cleaning, or maintenance is carried out with the engine running, dirt will get into the engine and damage it. Always stop the engine before carrying out these operations. When using compressed air, there is danger that dirt may be blown around and cause serious injury. Always use protective glasses, dust mask, and other protective equipment. Checking If air cleaner clogging caution lamp on the maintenance monitor flashes, clean the air cleaner element. For the location of the lamp, see “Warning Display” on page 2-8 and “Air Cleaner Clogging Caution Pilot Lamp” on page 2-12.
Do not clean the element until the air cleaner clogging caution lamp flashes. If you clean the air cleaner element frequently before the air cleaner clogging caution lamp flashes, the air cleaner will not be able to display its performance fully and the cleaning efficiency will drop. Cleaning the element too frequently also increases the likelihood that dirt stuck to the element will fall inside the inner element. Remark A dust indicator (5-stage display) is installed to the side of the air cleaner. The dust indicator shows the degree of clogging. This makes it possible to check how clean the element is and when it should be replaced.
Cleaning or Replacing Outer Element Remark When replacing the outer element, replace the inner element at the same time. 1. Stop the engine. 2. Open the door to access the air cleaner element. WA500-3LK 3-21