MAINTENANCE 3. Remove lock (1) from the cover, then remove cover (2). 4. Remove outer element (4). 5. Clean the inside and the cover of the air cleaner body. 6. Direct dry compressed air (less than 0.69 MPa (100.1 psi)) from the inside of the outer element along its folds. Then direct the compressed air from the outside along the folds, and again from the inside. Remove one seal every time the element is cleaned. Replace the outer element if it has been cleaned six times or used for one year. Replace the inner element at the same time.
Replace both inner and outer elements when the dust indicator red piston appears soon after installing the cleaned outer element even though it has not been cleaned six times. Remove actuator valve (3), then clean it with compressed air. After cleaning it, install it again. 7. After cleaning and drying the element, check it by shining a light through it. If any small holes or thin cracks are found, replace the element. When cleaning the element, do not hit it or beat it against anything. Do not use an element that has damaged folds, gaskets, or seals. 8. Replace the inner element. See “Replacing Inner Element” on page 3-23. 3-22 WA500-3LK