Komatsu — Clean Inside of Cooling System

MAINTENANCE 5. Check that the surface of the radiator cap is cool enough to be touched by hand. Turn radiator cap (2) slowly to release the pressure. 6. Remove the radiator cap. 7. Set a container in position to catch the antifreeze mix. 8. Open drain valve (3) at the radiator lower tank and drain plug (4) of the engine; drain the coolant. 9. After draining the coolant, close drain plugs (3) and (4). 10. Fill with tap water. 11. When the radiator is full, start the engine and run it at low idle. Keep the engine running at low idle for 10 minutes until the coolant temperature reaches more than 90°C (194°F). 12. Stop the engine. 13. Open drain plugs (3) and (4) and drain the water. 14.

After draining the water, clean the cooling system with cleaning agent. Follow the instructions provided with the cleaning agent. 15. Close drain plugs (3) and (4). 16. Replace the corrosion resistor. Set valve (1) to the OPEN position. For details about replacing the corrosion resistor, see “Replace Corrosion Resistor Cartridge” on page 3-62. 3-26 WA500-3LK