Check Accumulator Function MAINTENANCE For details about handling the accumulator, see “Accumulator” on page 1-40. 1. Stop the machine on level ground. 2. Apply the parking brake. 3. Raise the work equipment to the maximum height (A) and then place the lift arm control lever at HOLD. 4. Leave the work equipment in this position and stop the engine. 5. Confirm that the area around the machine is safe; then set the lift arm at FLOAT (B) and lower the work equipment to a position 1 m (3.28 ft) (C) from the ground. 6. When the work equipment reaches the position (C), move the lift arm control lever to LOWER and lower the work equipment slowly to the ground.
If the work equipment stops moving during the inspection, the gas pressure may be below the service limit (0.69 MPa (100.08 psi). Contact your Komatsu distributor to have the gas pressure measured or the gas charged. Remark Carry out the check within five minutes after stopping the engine. If the machine is left with the engine stopped, the accumulator pressure will drop and it will be impossible to do the check. Check Accumulator Gas Pressure When carrying out the EVERY 2000 HOURS SERVICE or the EVERY YEAR SERVICE, or when making periodic replacement of the critical safety parts, ask your Komatsu distributor to check the accumulator gas pressure.
Check Injector Check the exhaust gas color visually. If there is any abnormality in the exhaust gas color, contact your Komatsu distributor for inspection or replacement. For details about the action to take if there is an abnormality, see “Engine” on page 2-128, “Exhaust gas occasionally turns black.” WA500-3LK 3-71