Lubrication Controller Display Table OPTIONS, ATTACHMENTS WA500-3LK 5-9 Type Item Symptom LED Display 7-Segment Display When normal Counting When normal Power source LED lights up Flashes or numeral flashes Greasing I Pump operating Greasing LED lights up II Maintaining pressure Greasing LED flashes slowly (1 time/sec.) III Releasing pressure Greasing LED flashes rapidly (2 times/sec.) Setting Set mode Set LED flashes Depends on each set mode When abnormal Abnormality in pump pressure Pressure does not rise within greasing time Warning LED flashes Abnormality in release of grease pressure Pressure still remains after pressure is released (reverse rotation) Abnormality in pressure detection Limit switch for pressure detection is already actuated before system is started.
Tank empty Number of times greasing has reached greasing frequency limit