Komatsu — Setting Greasing Time in Cold Areas

OPTIONS, ATTACHMENTS Setting the Greasing Time The set time and greasing frequency limit differ according to the operating condition and greasing plan for the machine. Set the following items to carry out suitable centralized greasing: Greasing interval (Hr): Greasing interval for automatic operation Greasing time (min): Length of time pump is operated for each greasing operation Greasing frequency limit (times): Number of times for operating pump before the 1000 cc grease cartridge is empty The settings when shipped from the factory: Greasing interval: 3 hours Greasing time: 7 minutes Greasing frequency limit:

50 times The grease level alarm is set to sound after 130 hours on the hourmeter (under normal operating conditions). Remark Be careful since the life of the grease cartridge is shortened if the greasing interval is shorter. If the greasing interval is shorter, the amount of grease dripping from the tip of the working machine increases. It may make the machine and surrounding area dirty. Set Code Table Setting Greasing Time in Cold Areas Cold temperatures cause the viscosity of the grease to increase, which creates greater resistance inside of the piping. It is necessary to extend the length of greasing operations to ensure that adequate grease reaches the components.

For example, if the machine is used at temperatures below -20°C (-4°F), set the greasing time to 20 minutes (code No. 7). In addition, use lithium-based grease No. 0. When changing the set value, consult your Komatsu distributor. Remark When using the machine at ambient temperatures of below -20°C (-4°F), set to greasing time (b) at code No. 7. 5-10 WA500-3LK