Komatsu — Adjusting Sensor

Setting Remote Positioner Stop Position OPTIONS, ATTACHMENTS 1. When RAISE stop display lamp (1) is illuminated, operate the boom lever to raise the lift arm to the desired height (above horizontal), then return the control lever to HOLD and press RAISE position set switch (2). RAISE stop display lamp (1) will go out and RAISE set pilot lamp (3) will flash for 2.5 seconds. When RAISE set pilot lamp (3) goes out and RAISE stop display lamp (1) illuminates, the RAISE stop position is recorded in memory and the setting is complete. 2.

When LOWER stop display lamp (4) is illuminated, operate the boom lever to lower the lift arm to the desired height (above horizontal), then return the control lever to HOLD and press LOWER position set switch (5). LOWER stop display lamp (4) will go out and LOWER set pilot lamp (6) will flash for 2.5 seconds. When LOWER set pilot lamp (6) goes out and LOWER stop display lamp (4) illuminates, the LOWER stop position is recorded in memory and the setting is complete. Adjusting Sensor This function offsets the error caused by the mounting of the potentiometer and makes it possible to detect the correct position data for the work equipment.

Remark Always carry out this function when replacing the controller potentiometer or work equipment. 1. Set the work equipment to the lift arm top end position. 2. Keep LOWER position set switch (1) and RAISE position set switch (2) pressed at the same time for at least three seconds. 3. When LOWER set pilot lamp (3) and RAISE set pilot lamp (4) illuminate, release the switches and set to the sensor adjustment mode. The LOWER set pilot lamp (3) and RAISE set pilot lamp (4) illuminate for two seconds. When both lamps go out, the offset is recorded in memory. 4. If the lamps flash in Step 3, the potentiometer output is not within the offset range; adjust the potentiometer mount.

Adjustment can be carried out at the position in Step 1. Remark After adjusting each potentiometer, always carry out Steps 1 and 2 again. Check that the condition in Step 3 is correct (the set lamps light up for two seconds and then go out). WA500-3LK 5-17