Komatsu — WHEN REQUIRED

. MAINTENANCE MAINTENANCE PROCEDURE CHECK AND MAINTENANCE AIR CONDITIONER Check Level of Refrigerant (gas) WARNING (C) Colorless, transparent: No refrigerant 4 - 35 (Only f or machines equippe d with an air conditioner If the ref rigerant used in the air conditioner ge ts into your eyes or on your hands, it may cause los s of sight or frostbite. D o not touch th e refrigerant. Never loo sen any part o f the refrigerant circ Do not b ring any flam e close to any point whe re the refrigerant ga s is leaking. If the le vel of t he re frigerant (gas) is low, the cooling effect will be reduce d.

Run the e ngine at high idle, a nd check th e flow of the refriger ant gas (R134a) in th e refrigerant circuit through th e sight glass ( 2) (inspectio n window ) of the recei ver (1) whe n the c ooler is running at high spe (A) No (B) So Lack of bubbles in r me bubbles i refrigerant REMAR K When t here are bubbles, the refrigerant g as level is lo w, so contact your K omatsu distributors to have refri gerant added. If the air conditi oner is run w ith the r efrigerant gas level low, it will cause damag e to the compressor.