. MAINTENANCE MAINTENANCE PROCEDURE Inspection and Maintenance Items CLEAN LINE FILTER, REMOVE DIRT If there is any abnormality in the pump or other hydraulic equipment, remove the dirt from inside the line filter as follows. Before removing the line filter, release the pressure inside the hydraulic circuit. For details, see "METHOD FOR RELEASING INTERNAL PRESSURE IN HYDRAULIC CIRCUIT (PAGE 4-40)". 1. Remove plug (2). 2. Using a bolt (10 mm (0.4 in)), remove filter (1). 3. Wash filter (1). Be careful to remove the dirt stuck to the side face of the filter when washing it. 4. Replace backup ring (3) and O-rings (4) and (5) with new parts. 5. Assemble filter (1) after washing it.
Tightening torque for plug (2): 181 ± 18.1 Nm (18.5 ± 1.85 kgm, 133.8 ± 13.4 lbft) After assembling the line filter again, bleed the air. For details, see "BLEEDING AIR FROM HYDRAULIC SYSTEM (PAGE 4-37)". 4 - 36 Inspection During Off Season Even during the off-season, operate the air conditioner for 3 to 5 minutes once a month to m aintain the oil film at al parts of the compressor.
Check, maintenance items Guideli Content of check, maintenance ne for maintenance interval Refrigerant (gas) Charge amount Twice a ye ar (spring, autumn) Air conditioner condenser Clogged fins Every 500 hours Compressor Operating condition Every 400 0 hours V-belt Damage, tension Every 250 hours Blower motor, fan Operating condition When req (does it make abnormal noise?) uired Control mechanism Operating condition (does it function normally?) When req uired Piping mounts Mounting condition, looseness at tightening or When req connecting portions, leakage of gas, damage uired