UPPERSTRUCTURE / Pilot Shut-Off Solenoid Valve REMOVE AND INSTALL PILOT SHUT-OFF SOLENOID VALVE CAUTION: Release any pressure in the hydraulic oil tank before doing any work. (Refer to BLEED AIR FROM HYDRAULIC OIL TANK on W1-4-1.) Removal 1. Remove bolts (3) (9 used) and washers (4) (9 used). Remove cover (2) from main frame (1). 1 2 3, 4 : 19 mm 2. Remove bolt (7). Remove connector (8). W1JB-02-11-002 5 6 7 : 17 mm 3. Remove hoses (5) (9 used). Attach identification tags to the removed hoses for reassembling. Cap the open ends. : 17mm, 19 mm 4. Remove bolts (10) (2 used) and washers (11) (2 used). Remove pilot shut-off solenoid valve (9) from plate (6).
8 5 W1JB-02-08-003 5 9 Footrest Travel Pilot Valve : 17 mm 6 W1JB-02-08-004 10, 11 W2-8-1