hitachi — REMOVE AND INSTALL SIGNAL CONTROL VALVE

UPPERSTRUCTURE / Signal Control Valve REMOVE AND INSTALL SIGNAL CONTROL VALVE CAUTION: Release any pressure in the hydraulic oil tank before doing any work. (Refer to BLEED AIR FROM HYDRAULIC OIL TANK on W1-4-1.) Removal 1. Remove bolts (3) (11 used). Remove covers (2, 4) from main frame (1). 3 2 4 : 19 mm 1. Remove all hoses and the connectors (2 used) from signal control valve (5). Attach an identification tag onto the removed hoses for assembling. Cap the open ends. 3 1 W1JB-02-05-001 1 4-Spool Solenoid Valve : 17 mm, 19 mm 2. Remove socket bolts (7) (4 used). Remove signal control valve (5) from bracket (6). 5 W1JB-02-05-004 5 8 mm 6 W1JB-02-10-001 7 W2-10-1