hitachi — REMOVE AND INSTALL FAN MOTOR

UPPERSTRUCTURE / Fan Motor 7. Remove bolts (17) (4 used) and washers (18) (4 used). Remove cover (19) from bracket (20). 17, 18 : 19 mm 8. Remove bolt (22) and clamp (21). Remove hoses (23) (2 used) from fan valve (26). Cap the open ends. W1JB-02-13-004 20 19 : 19 mm, 36 mm 9. Remove hose (24). Cap the open ends. 21 26 22 : 27 mm 10. Remove bolts (25) (8 used). : 19 mm 23 CAUTION: The bracket (29) assembly weight: 116 kg (255 lb) 11. Attach a nylon sling to bracket (29) and hold bracket (29). Remove bolts (27) (6 used) and washers (28) (6 used). Remove the bracket (29) assembly from shroud (12). 24 W1JB-02-12-004 25 12 19 mm W1JB-02-12-003 W2-12-2 12 27, 28 29