Toyota — TROUBLESHOOTING

2-20 INSPECTION 3. Transformer primary voltage inspection CN61 connector disconnected, AC plug connected and charging switch ON OK (200 to 220 V) Transformer defect NG (other than standard) To inspection 4 CN61 INSPECTION 4.

Magnetic switch voltage inspection CN66 connector disconnected AC plug connected, charging switch ON/ OFF operated) OK (200 to 220V) MSch defect NG (other than standard) To inspection 6 CN66 CN60 Measure- ment terminals 476AH or more (1) CN61-1 (U)-CN61-2 (V) (TAB side) (2) CN61-2 (V)-CN61-4 (W) (TAB side) (3) CN61-4 (W)-CN61-1 (U) (TAB side) Below 476AH (1) CN61-1 (U)-CN61-2 (V) (REC side) (2) CN61-2 (V)-CN61-3 (W) (REC side) (3) CN61-3 (W)-CN61-1 (U) (REC side) Tester range 250 VAC Standard 200 to 220 V Measurement terminals (1) CN66-1(R)-CN66-2(95)(REC side) Tester range 250 VAC Standard Charging buttons ON: 200 to 220 V, Charging bottoms OFF: 0 V