Toyota — GS

2-33 Estimated cause Inspection method Standard Remedial action THR contact defect THR contact inspection Measurement terminals: Between THR terminals 95 and 96 OK: Non operated state 0 Ω Operated state ∞ Ω NG: Non operated state ∞ Ω THR reset- ting by lever operation or MSch ASSY replacement Incomplete charging TF tap charger defect AC input voltage measurement Measurement terminals: Between TF tap charger terminals  Change the wiring to match the input voltage Missing phase in input power supply Voltage measurement at mains outlet for power supply Measurement terminals: Between mains outlet terminals OK:

200 to 220 V (Charger for 200 V) 380 to 440 V (Charger for 400 V) In case of a missing phase, repair after check- ing the cause. THR tripping THR continuity inspection Measurement terminals: Between THR terminals 95 and 96 OK: Non operated state 0 Ω Operated state ∞ Ω NG: Non operated state ∞ Ω Reset lever operation after check- ing the THR tripping cause Dch defect (open circuit) Inspection of Dch resistance in forward and reverse directions Measurement terminals: Both terminals (anode and cathode) of Dch Anode Cathode Forward: Anode − Cathode + Reverse: Anode + Cathode − OK: Forward Several ten or more Reverse ∞ Ω NG:

Forward ∞ Ω Reverse ∞ Ω Dch replacement Disconnection of TF coil Measurement terminals: Between TH coil terminals OK: Continuity NG: ∞ Ω TF replacement MSch contact defect MSch secondary voltage measurement Measurement terminals: Voltage mea- surement between MSch terminals U, V and W OK: 200 to 220 V (Charger for 200 V) 380 to 440V (Charger for 400 V) NG: 189 V or less (Charger for 200 V) 319 V or less (Charger for 400 V) MSch contact repair or MSch ASSY replacement TF terminal tighten- ing defect Inspection of each TF terminal tightening state No loosening of each terminal Retightening of each termi- nal Timer setting at short time Setting time check in test mode See timer test section.

AMT replacement