2-32 TROUBLESHOOTING Estimated cause Inspection method Standard Remedial action The thermal relay on the AC side is tripped as soon as charging starts Short circuit of MSch MSch coil continuity inspection Measurement terminals: A and A 1 2 OK: Several hundred Ω NG: Abnormally low resistance MSch replacement TF insulation defect or short circuit between coils TF insulation inspection Measurement terminals: Between each coil and frame Inspection of short circuit between TF primary and secondary coils Measurement terminals: Between pri- mary and secondary coil terminals OK: 0.2 MΩ or more NG: Less than 0.2 MΩ OK: 0.2 MΩ or more NG:
Less than 0.2 MΩ TF replacement Dch defect Dch resistance inspection in forward and reverse directions Measurement terminals: Both terminals (anode and cathode) of Dch Anode Cathode Forward: Anode − Cathode + Reverse: Anode + Cathode − OK: Forward Several 10 Ω or more Reverse ∞ Ω NG: Forward 0 Ω → Reverse 0 Ω Dch replacement Other short circuit in main circuit Inspect the short-circuited portion by separating each circuit. Repair of defective por- tion Charging does not start though operated correctly for starting charging. Interruption or missing phase of input power supply Voltage measurement at main outlet for power supply Measurement terminals: Between outlet terminals OK:
200 to 220 V (charger for 200 V) 380 to 440 V (charger for 400 V) NG: 0 V In case of missing phase, repair after check- ing the case. Disconnection in the AC plug Voltage measurement between R, S and T terminals of MSch OK: 200∼220V (charger for 200 V) 380 to 440 V (charger for 400 V) NG: 0 V Repair the plug if any phase is missing or no voltage is detected. Blown fuse on DC side DC side fuse continuity inspection Measurement terminals: Both terminals of fuse OK: 0 Ω NG: ∞ Ω Fuse replacement MSch coil discon- nection MSch coil continuity inspection Measurement terminals: Between MSch terminals A and A 1 2 OK: Several hundred Ω NG:
∞ Ω MSch replacement AMT defect AMT inspection Measurement terminals: Between AMT terminals 1 and 5 in wiring diagram OK: 0 V NG: 200 V (Charger for 200 V) 400 V (Charger for 400 V) AMT replacement