2-41 Inspection after Reassembly 1. Inspect each wiring for correctness. Note: Check correct wiring at each part by referring to the charger wiring diagram. 2. Inspect the transformer insulation resistance. 3. Measure the no-load secondary voltage. Connect the charger plug to the charger receptacle and start the timer.
AC voltage DC voltage Measurement terminals Between each coil and frame Standard value 0.2 MΩ or more Circuit tester range AC 250 V · AC 500 V Measurement terminals U −V , V −W and W −U 2 2 2 2 2 2 Standard value See the Service Standards list Circuit tester range 250 VDC Measurement terminals Both terminals of charger plug (+) terminal − (+) probe (−) terminal − (−) probe Standard value See the Service Standards list.