2-42 AMT Test Method 1. Main timer inspection (1) Turn on the AC power switch. (2) Disconnect the battery plug. (to unload the charger and operate the voltage relay.) (3) Close the magnetic switch (MSch) forcibly by using an insulating bar and press the NORMAL button (black-blue) or EQUAL button (black-blue) for 5 seconds or more until the TEST LED (red) and CHARGING PROGRESS INDICATOR LEDs (three LEDs excluding the uppermost one) light up. Release the button as soon as they light up, and measure with a stop watch the time until the uppermost LED comes on.
(4) If the UP LED lights up within the following period of time after TEST LED lights up and all LEDs then immediatelly go out, the main timer is functioning normally. When NORMAL button is pressed: UP LED lights up in about 6 seconds later When EQUAL button is pressed: UP LED lights up in about 18 seconds later 2. Total timer inspection (1) Turn on the POWER switch. (2) Connect the battery in discharged state (as the main timer is operated first because of voltage relay operation in the fully charged state). (3) Press the NORMAL or EQUAL button for 5 seconds, the TEST LED lights up and charging starts.
Release the button when the TEST LED lights up and measure with a stop watch the time until the CHECK LED lights up. (4) If the CHECK LED lights up within the following period of time after the TEST LED lights up, the total timer is functioning normally. (The UP LED does not light up.) CHECK LED lights up in 90 to 100 seconds (5) The LED go off when the battery plug is disconnected. Caution: If the NORMAL, EQUAL or STOP button is pressed when a fully charged battery is connected, the main timer operates first to light the UP LED and not the CHECK LED. This does not indicate a total timer defect. Inspect again as described above after replacing the battery with a discharged one.