Toyota — YUASA

2-50 Estimated cause Check method Standard Remedial action The ammeter does not defect. Blown Fch Fch conduction check Measurement terminals: Both termi- nals of Fch OK: 0 Ω NG: ∞ Ω Fch replacement Open circuit in TF TF coil conduction inspection Measurement terminals: Between TF terminals OK: 0 Ω NG: ∞ Ω TF replacement Dch defect (open circuit) Dch forward and reverse resistance inspection Measurement terminals: Both termi- nals of Dch Forward Forward: Anode − Cathode + Reverse: Anode + Cathode − OK: Forward: Over 10 kΩ Reverse: ∞ Ω NG: Forward: ∞ Ω Reverse: ∞ Ω Dch replacement Ammeter defect Inspection of conduction between ammeter terminals Measurement terminals:

Both termi- nals of ammeter OK: Over 10 Ω or less NG: ∞ Ω Ammeter replacement Insufficient charging or total timer actuation (CHECK LED ON) Lacking phase in AC power supply Voltage measurement at input recep- tacle Measurement terminals: Between receptacle terminals OK: 200 to 230 V (Charger for 200 V) 340 to 460 V (Charger for 400 V) NG: 0 V Repair after checking the cause for lacking phase Improper TF tap changer setting Input AC voltage measurement Measurement terminals: Between TF tap changer terminals  Wiring change to the taps match- ing the input voltage MSch contact defect Measurement of secondary voltage at MSch contacts Measurement terminals: MSch, U, V and W terminals OK:

200 to 230 V (Charger for 200 V) 340 to 460 V (Charger for 400 V) NG: 189 V or less 329 V or less MSch con- tact repair or MSch replacement Open circuit in TF TF wiring conduction inspection Measuring terminals: TF coil terminals OK: 0 Ω NG: ∞ Ω TF replacement Dch defect (open circuit) Dch forward and reverse resistance measurement Measurement terminals: both termi- nals of Dch Forward Forward: Anode − Cathode + Reverse: Anode + Cathode − OK: Forward: Over 10 kΩ Reverse: ∞ Ω NG: Forward: ∞ Ω Reverse: ∞ Ω Dch replacement Microcomputer timer (BMT) defect Set time check in test mode See page 2-21 BMT replacement