Doosan Mega 500-V (Tier II) — Fault Code Information

S0802195K Page 39 Electrical System Fault Code Light J1587 PID(P) SID(S) FMI J1939 SPN FMI Reason Effect 151 Red P110 0 110 0 Coolant temperature signal indicates coolant temperature above 104°C [220°F]. Progressive power derate with increasing time after alert. If Engine Protection shutdown feature is enabled, engine will shut down 30 seconds after red light starts flashing. 153 Yellow P105 3 105 3 High voltage detected at the intake manifold temperature circuit. Possible white smoke. Fan will stay on if controlled by electronic control module (ECM). No engine protection for coolant temperature. 154 Yellow P105 4 105 4 Low voltage detected at the intake manifold temperature circuit.

Possible white smoke. Fan will stay on if controlled by electronic control module (ECM). No engine protection for coolant temperature. 155 Red P105 0 105 0 Intake Manifold temperature signal indicates temperature above 87.7°C [190°F]. Progressive power derate with increasing time after alert. If Engine Protection shutdown feature is enabled, engine will shut down 30 seconds after red light starts flashing. 187 Yellow S232 4 620 4 Low voltage detected on the ECM voltage supply line to some sensors (VSEN2 supply). Engine will run derated. No engine protection for oil pressure and coolant level. 211 None A216 11 1484 31 Additional OEM or Vehicle diagnostic codes have been logged.

Check other ACME’s for diagnostic codes. None on engine performance. 212 Yellow P175 3 175 3 High voltage detected at the oil temperature circuit. No engine protection for oil temperature. 213 Yellow P175 4 175 4 Low voltage detected at the oil temperature circuit. No engine protection for oil temperature. 214 Red P175 0 175 0 Oil temperature signal indicates oil temperature above123.9°C [255°F] Progressive power derate with increasing time after alert. If Engine Protection shutdown feature is enabled, engine will shut down 30 sec. after red light starts flashing. 219 Maintenance P017 1 1380 17 Low oil level was detected in the Centinel makeup oil tank. None performance.

Centinel deactivated. 221 Yellow P108 3 108 3 High voltage detected at the ambient air pressure circuit. Derate in power output of the engine 222 Yellow P108 4 108 4 Low voltage detected at the ambient air pressure circuit. Derate in power output of the engine 223 Yellow P085 4 1265 4 Incorrect voltage detected at the Centinel actuator circuit by the ECM. None n performance. Centinel deactivated. 227 Yellow P232 3 620 3 High voltage detected on the ECM voltage supply line to some sensors (VSEN2 supply). Engine will run derated. No engine protection for oil pressure and coolant level.