Doosan Mega 500-V (Tier II) — Fault Code Information

S0802195K Page 41 Electrical System Fault Code Light J1587 PID(P) SID(S) FMI J1939 SPN FMI Reason Effect 288 Red S029 2 974 19 The OEM vehicle electronic control unit (VECU) detected a fault with its remote throttle. The engine will not respond to the remote throttle. 293 Yellow S154 3 1083 3 High voltage detected at the OEM temperature sensor signal pin of the 31-pin OEM connector. No engine protection for OEM temperature. 294 Yellow S154 4 1083 4 Low voltage detected at the OEM temperature sensor signal pin of the 31-pin OEM connector. No engine protection for OEM temperature. 295 Yellow S108 2 108 2 An error in the ambient air pressure sensor signal was detected by the ECM.

Engine is derated to no air setting. 297 Yellow S223 3 1084 3 High voltage detected at the OEM pressure sensor signal pin of the 31-pin OEM connector. No engine protection for OEM pressure 298 Yellow S223 4 1084 4 Low voltage detected at the OEM pressure sensor signal pin of the 31-pin OEM connector. No engine protection for OEM pressure 299 Yellow S117 11 1384 31 Engine shutdown by device other than key switch before proper engine cool down resulting in filtered load factor above maximum shutdown threshold. No action taken by the ECM. 311 Yellow S001 6 651 6 Current detected at No.1 injector when voltage is turned off. Current to injector is shut off.

312 Yellow S005 6 655 6 Current detected at No.5 injector when voltage is turned off. Current to injector is shut off. 313 Yellow S003 6 653 6 Current detected No.3 injector when voltage is turned off. Current to injector is shut off. 314 Yellow S006 6 656 6 Current detected No.6 injector when voltage is turned off. Current to injector is shut off. 315 Yellow S002 6 652 6 Current detected No.2 injector when voltage is turned off. Current to injector is shut off. 319 Maintenance S251 2 251 2 Real time clock lost power. None on performance. Data in the ECM will not have accurate time and data information. 321 Yellow S004 6 654 6 Current detected No.4 injector when voltage is turned on.

Current to injector is shut off. 322 Yellow S001 5 651 5 No current detected at No.1 injector when voltage is turned on. Current to injector is shut off. 323 Yellow S005 5 655 5 No current detected at No.5 injector when voltage is turned on. Current to injector is shut off. 324 Yellow S003 5 653 5 No current detected at No.3 injector when voltage is turned on. Current to injector is shut off. 325 Yellow S006 5 656 5 No current detected at No.6 injector when voltage is turned on. Current to injector is shut off. 331 Yellow S002 5 652 5 No current detected at No.2 injector when voltage is turned on. Current to injector is shut off.

332 Yellow S004 5 654 5 No current detected at No.4 injector when voltage is turned on. Current to injector is shut off.