Komatsu — CLEAN INSIDE OF COOLING SYSTEM

. MAINTENANCE MAINTENANCE PROCEDURE MAINTENANCE MAINTENANCE PROCEDURE tighten it. 4 - 25 5. securely with the cover suppo (See "BATTERY INSPECTIO 6. Place a container to catch th e coolant under the drain hose installed to drain valve (2) an d under coolant drain plug (3) on the engine block. n the water. 7. Open drain valve (2) and drai Remove drain plug (3) from th e engine cylinder block and drain the water. 8. After draining the antifreeze s olution, close drain valve (2) and tighten drain plug (3), then fill with clean water. After the radiator is filled with water, sta rt and run the engine at low idling speed. After the water temp erature rises above 90°C (194° 0 minutes.

rain valve (2) and remove drain F), run the engine for about 1 Stop the engine, then open d plug (3) to drain the water. 11. Add coolant mixed with antifr eeze until it overflows from the water filler. Decide the proportions of antif reeze and water according to the table for the mixing rate of water and antifreeze. 12. To remove air in the cooling (While doing this, leave the ra 13. Drain the coolant from sub-t sub-tank, then add water until the coolant level is between the FULL and LOW marks. 14. Stop the engine, wait for appr ox. 3 minutes, then add coolant until the coolant level is near the coolant filler port, and tighten the cap. Check the coolant level and add coolant if necessary.

until the coolant level is near t the cap. Check the coolant le he coolant filler port, and tighten vel and add coolant if necessary.