. MAINTENANCE SERVICE PROCEDURE SUSPENSION CYLINDER, SPRING 4 - 54 CHECK OF ACCUMULATOR GAS PRE For handling of (PAGE ACCUMULATOR, GAS REMARK If the engine stops d uring travel , the brake c an be operate d wit h the o il pressure in the accumulato r temporarily CHECK OF FUNCTIO 1. Sto p the machin e on a flat p lace and set the parking b rake switch to the PARKING position 2. Star t the engine and r un it a t medium sp eed for 1 minute, a nd the n stop i 3. Tur n the starting switc h to th e ON positio n and depress the brake pedal s everal times.
After the brake pedal is depressed some times , the brake oil pre ssure caution lam p lights If the brake o il pressure caution lamp lights up whe n the brake pedal is depressed 4 times o r less, the gas ressure in th e accumulator may be l ow. Ask your Komatsu di stributo r for inspectio If the brake o il pressure caution lamp does not light up w hen th e brak e peda l is depressed 5 times, the gas ressure in th e accumulator is norma REMARK Check t he function w ithin 5 minutes after sto pping the engine. If the en gine is kept stopped, the gas pressure in the accumulator lowers and c annot be checked.