mercedes-benz — Mercedes-Benz Unimog 421-411 Service Workshop Manual Volume 1

43.3 General Fault Cause Remedy Defrosting Pump Thrust tappet is too loose no counter-pressure felt or liquid level does not drop after repea ted operation. Piston seal leaking or strainer or supply bore choked. Fit new piston seal. Clean strai ner or supply bore. Air escaping at thrust tappet guide in replenishing tank. Valve chamber dirty or valve head damaged. Remove valve head. Clean valve chamber. Replace or recondition valve head. Drainage Valve Drainage valve leaking. Actuating valve or valve seat dirty or defective. Briefly operate actuating valve. Clean or replace valve or valve seat. Brake Servo Unit Leaks. Rubber parts or valves defecti ve. Replace rubber parts or valves.

Functional faults. Piston, piston liner or piston rod show signs of damage. Replace assembly. Double Pressure Gauge Single-circuit air brake system: Gauge not acu rate can be che cked by fully applying brakes. Tank and brake pressure poin ters must agree. Incorrectly connected. Instrument defective. Connect correctly. Replace instrument. Brake Pressure Warning Light Warning light comes on when travelling. Brake pressure inadequate or non-existent. Watch double pressure gauge, replenish tank pressure. Check brake system for leaks.