General 43.3 Troubleshooting Compressed Air System without EEC system Repairs to assemblies may only be performed by authorized workshops and brake service points. Fault Cause Remedy Pressure Regulator with Air Filter and Tire Inflating Port Cut-in pressure excessive or inadequate. Pressure regulator incorrectly adjusted. Adjust to cut-in pressure; refer to technical data "Pressure regula tor". air compressor over to idling. Passage choked. Control piston sticking. Grooved ring defective. Clean passage. Check control piston and grooved ring, repla cing if necessary. Pressure regulator fails to switch Pressure regulator fails to switch air compressor over to on-load operation.

Vent choked, intake valve lea king, adjusting spring defective, sealing ring leaking. Cut-off pi ston sticking. Clean vent, clean or replace val ve. Check or replace spring. Replace sealing ring. Check cut off piston and sealing ring. Compressed air escapes from drain socket in charging position. Safety or no-load valve leaking. Clean or replace valve and valve seat ring. Pressure regulator loses com pressed air at vent in no-load or Intake valve leaking. Spring de fective. Clean or replace valve. Replace spring. charging position. Pressure regulator does not ad mit compressed air to air tank. Filter choked. Clean or replace filter.

Compressed air escapes from dust cap on tire inflating port. Valve leaking. Check or replace valve. Brief operating interval between pressure regulator cut-in and cut-out. Heavy air consumption. Check valve leaking. Check compressed air system for leaks. Clean or replace valve. Defroster Compressed air escapes from actuating rod. Sealing ring leaking. Replace sealing ring. Check sea ling surface on rod. Compressed air escapes from mounting flange of reservoir. 0-ring leaking. Replace 0-ring. Steady consumption of antifree ze in closed position. Sealing ring leaking. Replace sealing ring. f d t k ti N tif l ft M t D i t d t ith ti