mercedes-benz — Mercedes-Benz Unimog 421-411 Service Workshop Manual Volume 1

Control Equipment 43.3 Pressure Regulator with Tire Inflation Connection Operation Air coming from the compressor is forced via connec tion 2 through filter 3, inlet 4 via chamber 7 past check valve 13 into the line to the air tank. When the cutout pressure is attained, piston 11 is moved against spring 10. Breather 9 for chamber 15 is closed and intake 12 is opened. The pressure entering chamber 15 energizes the shut off piston to open safety valve 1. The air compres sor operates at no-load until pressure in chamber 8 drops below cut-in pressure. If this is the case, piston 11 returns, intake 12 is closed and chamber 15 evacuated. Safety valve 1 is closed and the air tank is filled.

To use tire inflation connection, unscrew cap 6. Valve 5 is opened when tire inflation hose is screwed on. Note: For inflating tires, supply pressure must be below cut-in pressure 6.2 bar of pressure regulator. Removal and Installation 1 Safety valve 2 Connection, air compressor 3 Filter 4 Inlet 5 Valve 6 Protective cap 7 Chamber 8 Chamber 9 Breather 10 Spring 11 Piston 1 Make system pressureless prior to starting. 1 2 Connection, air tank 13 Check valve 14 Inlet 15 Chamber 16 Connection, special equipment E Breather 2 Loosen pipe connections of supply lines. 3 Unscrew fastening bolts on bracket for pressure regulator. 4 Remove pressure regulator.

Disassembly, Inspection and Assembly 1 Clean unit externally P3 solution, compressed air. 5 Reassembly takes place in the reverse sequen ce. Note: When reconnecting piping, use new sealing rings fibre. 2 Unscrew hose connection or filter housing after removing locking ring. 3 Remove filter element, carefully clean in Nitro N7 and re-install only when dry. 6 Check system for leaks dab test points with soapy water. Note: Apart from removing filter housing, further disassembly of pressure regulator is not required for cleaning filter element