43.3 Control Equipment Pressure Regulator without Tire Inflation Connection Outlet 16 then closes and inlet 14 opens so that the compressed air in chamber b also flows into chamber c above piston 13. The subsequent down ward movement of piston 13 opens idle speed valve 1 2. The air continuously supplied by the compres sor can escape through the idle speed connection directly into the atmosphere. Piston 13 keeps idle speed valve 12 open due to the pressure still acting on the upper end in chamber c. The air compressor continues operating at idle speed until the pressure in chamber b drops below the cut in pressure of the pressure regulator due to the air consumed in the system.
Diaphragm piston 15 is then pushed down again by compression spring 4. Inlet 14 closes and chamber c is evacuated via outlet 16 which opens as well as via breather opening E. The resulting relief of piston 1 3 closes idle speed valve 12 and the air tank is then filled up again to cut-out pressure. Note: Tire inflation connection 000 431 14 31 is at the same time the test connection and is located on the compressed air tank.
1 Connection, air compressor 2 Connection, air tank 3 Adjusting screw 4 Compression spring 5 Check valve 10 Filter 1 2 Idle speed valve 13 Piston 14 Inlet 15 Diaphragm piston 16 Outlet 11 Idle speed connection E Breather opening Operation Maintenance Compressed air coming from compressor is forced via connection 1 through filter 10 into chamber a and check valve 5, past connection 2 into line to air tank. Depending on operating conditions - normally every three months - remove filter 10 after taking off bottom of housing, carefully clean in Nitro N7 and re install only when dry.
If the setting of the pressure regulator has changed, reset correct cut-out pressu re 7.3 bar at adjusting screw 3. Simultaneously, the pressure is built up in chamber b below diaphragm piston 15, which is moved upward i t i i 4 h th t t