mercedes-benz — Mercedes-Benz Unimog 421-411 Service Workshop Manual Volume 1

Battery 54.9 Recharging Note: If, when checking the battery, it was found that the electrolyte density of the specific density is less than 1 .20 in tropics less than 1 .17, the battery must be recharged. The charging current of the battery 110 Ah is not more than 11.0 Amperes and must not be exceeded. 1 Before recharging battery, check electrolyte level 10 to 12 mm above upper edge of plates. Top up if necessary. 2 Connect battery to external source of DC current. 3 When charging, the electrolyte temperature in creases form 15 ° C to 40 ° C. It is only possible to accurately measure the electrolyte density half an hour after charging.

4 When charging the battery, note that gas esca pes evenly out of each cell and that the voltage of 2.6 to 2.7 Volts is reached at each cell. Gasing increases towards the end of charging. 5 Recharging is complete when the electrolyte density has reached 1 .285 and the terminal voltage of each cell is 2.6 to 2.7. Measure the voltages with the charging current switched on and the electrolyte density at the specified electolyte level. 6 Batteries with sulphated plates, recognizable from the white deposit or from the low specific density below 1.12, must be charged for 40 hours with 2.5 Amperes followed by final charging at full charging current.

Batteries not in use require regular care to maintain them in a serviceable condition. Re-charge once at least every 8 weeks. Failure to do this will render the battery unusable.