mercedes-benz — Mercedes-Benz Unimog 421-411 Service Workshop Manual Volume 1

4. Check acid density at a temperature of +200 C. the spindel, is level with the acid upper edge. Picture 54-1/2 and 54-1/3. Page Lift up just enough acid use acid lifter to make the spindel float. The battery is well charged when the no. 1.285, stamped on 15/54-0/2 lists the various nominations for acid density and specific weight, also the load condition of the battery. -I *1- 1 Picture 54-1/4 Check battery cell Picture 54--1/2 Check acid density Picture 54-1/3 1 Acd lifter 000 589 01 27 00 2 - Lock cover 1 = cell lester 000 589 00 2700 Remark: Batteries not in use all the times, need special care to keep them alive.

At least every 6-8 weeks recharge, if not done so, battery becomes unserviceable. C. Battery recharge Remark: An exact measurement can only be done when battery is cooled off. If noticed, the acid density, resp. the specific weight drops below 1.20 in tropics below 1.17, the battery must be recharged. 4. Each cell of the battery must equally deve 2.6-2.7 V. Picture 54-1/4. Gas developing lop gas, each cell should have a current of The max. charging current of the battery is: a On type 421 88 Ah 9.0 Amps. increases when battery charging comes to b On type 411 105 Ah 9.5 Amps. its end.