Removing and installing coolant regulator 20,9 615 621 Removal and installation 1 Drain coolant. With antifreeze collect contents. Drain plug is underneath the radiator. 5 Check regulator element for function and, if required, exchange. The coolant regulator is best tested in a container with hot water in which a thermometer is immersed. The regulator should begin to open at 79 ° + 1 0 C and entirely open at 91 ° + 3 ° C. 2 Remove upper coolant hose of coolant regulator. 3 Unscrew pipe sockets and remove gasket. 4 Remove regulator element. Important! When reinstalling, the vent valve bore for radiator must be located on the side of the coolant connec tion, i. e. at the highest point.
-5 1- Main valve opened Stroke a 8 to9 mm at approx. 91 ° to 94 °C. By-pass line closed A B- A from engine S 10 radiator A pressure relief valve in the coolant expansion tank connection ensures an overpressure of 0.4 bar in the system. Consequently the boiling temperature is increased in sea level from 1000 to 108 ° C. Main valve closed By-pass valve fully opened Stroke b 7.5 to 8 mm Note: Repairs cannot be made to the regulator element. Unusable regulator elements are to be replaced. 1 000lanI regulator 2 SeatIng ring 3 Hexagon socket screw 4 Cover 6 Installation takes place in reverse sequence. 7 Fill with coolant Run engine and check hose