Checking ALB-regutator setting adjusting 42.3 Checking setting, adjusting to chassis end no. 013 170 The ALB-regulator must not be adjusted. Connect two manometers to respective test connections 1 and 2 of empty vehicle for hydraulic examination of the setting brake force distribution. Actuate foot- brake pedal until overpressure indicates 100 bar kp/cm 2 on the pressure gauge test connection 2. This value corresponds to unregulated overpressure before the ALB-regulator. An overpressure of 40 or 45 bar kp/cm 2 must then exist at the secound pressure gauge test connecton 1. This value corresponds to the regulated overpressure after the ALB-regulator. Adjustment after lengthy driving:
When loaded perm. payload the pointer must agree with the housing mark on the actuating shaft. The regulator lever should be at least horizontal on the serration and if possible point even 3 to 4 ° upward. Due to negligible settling springs, the pointer can be offset to the left. Remedy: adjust control rod in its length by turning ball heads until pointer and housing mark are aligned. Observe sign in driver’s cab for adjusting reg. valve. Perform adjustment only at control rod. The control rod must be attached to the correct bore of the regulator lever. See table. Brake force control:
Nominal values vehicle load bar kplcm2 unloaded bar kp/cm2 100:1 00 100:40– Regulator lever bore Middle Lever arm length mm 92 Distance mm after Installation spacere 86 Corresponding rear axle load kp approx. 2400