42.3 Checking ALB-regulator setting, adjusting Checking setting, adjusting Westinghouse regula tor From chassis end no. 013 171 1 For checking, detach fail-safe device control spring from troques tube. 2 Connect pressure gauge of the tester to both test connections in front of and behind the ALB-regulator. 1 Test connection regulated 2 Test connection unregulated 3 Slowly depress brake footpedal fully, at the same time both pressure gauges uniformly climb up to the fail-safe pressure of 26 to 30 bar, then the pressure gauge of the regulated circuit must stop. 4 Adjust as required pressure of the regulated circle to 26 to 30 bar at adjustment screw 1. 5 Attach control spring at torque tube.

6 For checking the load-dependent throttle control, determine rear axle load in vehicle ready for driving weigh. 7 Fully depress brake footpedal until approx. 140 bar in so doing the pressure gauge pointer of the regulated circuit must remain within the specialfied pressure range see diagram. 8 If required, adjust the control pressure by shifting control spring in elongated hole at torque tube. Note: Shorten spring travel. Control pressure is reduced. Lengthen spring travel. Control pressure is increased.