Komatsu — Komatsu PC308USLC-3E0 Hydraulic Excavator Operation & Maintenance Manual

. OPERATION MACHINE OPERATIONS AND CONTROLS on the internal structure of the engine at idling for more than 20 minutes, apply a load from time to time or run at a mid-range speed. temperature monitor (1) displays procedure in Step 3 to carry out until the monitor displays run the engine at a mid-range load until engine water temperature 3 - 91 Engine Warm Up NOTICE Do not accelerate the engine sudde been completed. Do not run the engine at low idling o than 20 minutes. This will have an and will also have an adverse effe engine. If it is necessary to run th After the engine starts, do not start operating the machine immediately. First, carry out the following operations and checks. 1.

This machine is equipped wit below 30 °C after the engine i automatic warm-up operation s speed. If the engine water temperature 10 minutes, the automatic war speed. h an automatic engine warm-up system, so if the engine water temperature is 1. 1. below 30 °C after the engine i s started, the engine warm-up operation starts automat ically. When the engine automatic warm-up operation s tarts, the engine speed is maintained at a speed higher t han the normal low idling speed.

If the engine water temperature goes above 30 °C or if the warm-up operation has been continued for more than 10 minutes, the automatic war m-up operation is cancelled and the engine speed drop s to the normal low idling speed. 2. Check that engine water tem green. If it displays white, use the pr additional warm up of the en green. 3. Turn fuel control dial (2) to a p (MIN) and full speed (MAX), speed, and run under no load monitor (1) displays green. If the engine water temperature m onitor displays green, the engine warm-up operation is completed. After checking that the engine wate r temperature monitor displays green, carry out the war ming-up operation for the hydraulic equipment.