MAN — Man EPA07 Series 60 Engine Operator's Manual

OPERATING INSTRUCTIONS FOR STARTING THE ENGINE Important: Before starting the engine, carefully read all operating instructions in this manual and do all the recommended pretrip inspections and daily maintenance. Check the engine oil and fuel levels, and drain contaminants from the fuel/water separator (optional). 4. Shut down the engine. 5. Approximately five minutes after shutdown, check the engine oil level. If necessary, add oil up to the satisfactory fill range on the oil dipstick (see Figure 9). Do not overfill. NOTE: If you drain the fuel/water separator completely, you may have to prime the fuel system. NOTE:

As a safety function, the electronic engine control system may be wired to start the engine only If the transmission is in neutral. This is vehicle application specific. Figure 9 Oil Dipstick 6. Check all the mounting fasteners on the engine for tightness. 1. Turn on the ignition switch. 2. With the accelerator pedal in the idle position, start the engine. Checking the Coolant Level (Cold Check) 3. Check the engine for leaks. [a] Check all hoses, hose clamps, and pipe unions on the engine for tightness. Shut down the engine and tighten them if necessary. Check coolant level as follows: 1.

Ensure that all coolant plugs in the bottom of the radiator and on the radiator outlet pipe are secure and tight. 2. Check the coolant level. The cooling system is correctly filled when the coolant is between the [b] Check the oil feed and return lines at the turbocharger for tightness. Shut down the engine and tighten them if necessary. 28 All information subject to change without notice. DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION