MAN — Man EPA07 Series 60 Engine Operator's Manual

EPA07 SERIES 60 ENGINE OPERATOR'S MANUAL maximum and minimum marks on the surge tank. briefly and the coolant level again checked and corrected as necessary. NOTE: For more information, refer to the “MAINTENANCE” section. Monitoring Engine Operation Checking the Coolant Level (Hot Check) While the engine is operating, monitor the battery charge indicator light, the oil pressure and avoid excessive idling. Check the coolant levels as follows: 1. Allow the engine to run for approximately five minutes at a moderate speed. Battery Charge The battery charge indicator light must go out once the engine starts.

See Figure 10 HOT COOLANT To avoid scalding from the expulsion of hot coolant, never remove the cooling system pressure cap while the engine is at operating temperature. Wear adequate protective clothing (face shield, rubber gloves, apron, and boots). Remove the cap slowly to relieve pressure. Figure 10 Battery Charge Indicator Light 2. Then, with the coolant temperature above 50°C (122°F), recheck the coolant level. If the indicator light comes on while the engine is running, do the following: 3. Add more coolant if necessary. Open the heater valves before adding coolant. 4. Do not close the heater valves until the engine has been run All information subject to change without notice.

29 DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION