EPA07 SERIES 60 ENGINE OPERATOR'S MANUAL Engine power and rpm fall, even though the accelerator pedal remains steady. NOTICE: The exhaust pipe gives off heavy smoke. To prevent possible serious engine damage, have any faults corrected without delay by an authorized dealer. The coolant and/or oil temperature climb abnormally. Abnormal sounds suddenly occur in the engine or turbocharger. In conjunction with any dashboard or instrument panel display, the code for the electronic control unit reporting the fault can be read immediately on the display. Shutting Down After High Load Operation If the fault is serious enough to impair normal operation, DDEC VI switches over to limp home mode.

The limp home speed is dependent on MCM parameters and could be idle speed or 1000 rpm. This allows you to move the vehicle to a service location. After high load operation, do the following: NOTICE: An engine running at full output or with high coolant temperature after a high load operation, should idle for one or two minutes without load. Shutting down without idling may cause damage to the turbocharger. Stop Engine Override Option The Stop Engine Override Option is used for a momentary override. The Motor Control Module (MCM) will record the number of times the override is activated after a fault occurs. Turn off the ignition switch and shut down the engine.

Emergency Running Mode The engine is equipped with DDEC VI which monitors the engine as it is running. As soon as a fault is detected, it is evaluated and one of the following measures is initiated. All information subject to change without notice. 31 DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION