OPERATING INSTRUCTIONS FOR STARTING THE ENGINE Momentary Override A Stop Engine Override (SEO) switch is used to override the shutdown sequence (see Figure 11). This override resets the 60 second (30 seconds for oil pressure) shutdown timer, restoring power to the level when the Red Stop Lamp (RSL)/Stop Enginewas illuminated. The switch must be recycled after five seconds to obtain a subsequent override. Cold Weather Operation Special precautions must be taken during cold weather. To protect your engine, special cold weather handling is required for fuel, engine oil, coolant, and batteries. For detailed information, refer to the service manual.

Winter Fronts A winter front may be used to improve cab heating while idling. At least 25% of the grill opening should remain open in sectioned stripes that run perpendicular to the charge air cooler tube flow direction. This assures even cooling across each tube and reduces header to tube stress and possible failure. Winter fronts should only be used when the ambient temperature remains below -12.2° C (10° F). Figure 11 SEO Switch and Warning Lamps NOTE: The operator has the responsibility to take action to avoid engine damage. 32 All information subject to change without notice. DDC-SVC-MAN-0006 Copyright © 2009 DETROIT DIESEL CORPORATION