Section 03 ELECTRONIC MANAGEMENT SYSTEMS Subsection 04 (MONITORING SYSTEM AND FAULT CODES) smr2009-029 197 FAULT CODE MODULE DESCRIPTION POSSIBLE CAUSE SERVICE ACTION C2252 iS TOPS active Warning only: TOPS detected by the system, the suspension is disable while the TOPS is "ON" Check for 12 volts on sensor connector pin A. Check continuity for circuits B-H1, B-H3. Check fuse 10 (refer to WIRING DIAGRAM) refer to the Service Manual for more details. C2260 iS System under voltage System under voltage warning Check battery and charging system. P0106 ECM Intake pressure sensor out of range Sensing port dirty or blocked. Sensor failure or unexpected reading at idle.
Sensor fallen out of housing or leaking inlet Check system circuits A-B4, A-G4, A-H2. Make sure that the sensor housing is correctly inserted into the manifold. Check sensor connector for: a) 5 volts on pin 1. b) 0 volt on pin 2. c) 0 volt on pin 3. Refer to the Service Manual for more details. P0107 ECM Manifold absolute pressure sensor shorted to ground Sensing port dirty or blocked. Sensor failure or unexpected reading at idle. Sensor fallen out of housing or leaking inlet Check system circuits A-B4, A-G4, A-H2. Make sure that the sensor housing is correctly inserted into the manifold. Check sensor connector for: a) 5 volts on pin 1. b) 0 volt on pin 2. c) 0 volt on pin 3.
Refer to the Service Manual for more details. P0108 ECM Manifold absolute pressure sensor open circuit or shorted to battery Sensing port dirty or blocked. Sensor failure or unexpected reading at idle. Sensor fallen out of housing or leaking inlet Check system circuits A-B4, A-G4, A-H2. Make sure that the sensor housing is correctly inserted into the manifold. Check sensor connector for: a) 5 volts on pin 1. b) 0 volt on pin 2. c) 0 volt on pin 3. Refer to the Service Manual for more details.
P0112 ECM Intake manifold temperature sensor shorted to ground Damaged sensor, damaged circuit wires, damaged connector or damaged ECM pins Check the sensor for approximately 2280 to 2736 ohms at 19 to 21°C (66 to 70°F). Check for approximately 2280 to 2736 ohms at 19 to 21°C (66 to 70°F) between ECM connector pins A-H3 and A-J3. Refer to the Service Manual for more details.