Section 03 ELECTRONIC MANAGEMENT SYSTEMS Subsection 04 (MONITORING SYSTEM AND FAULT CODES) 196 smr2009-029 FAULT CODE MODULE DESCRIPTION POSSIBLE CAUSE SERVICE ACTION C2151 iBR System disabled and need activation System is locked. Need activation Use B.U.D.S. iBR unlock function. Refer to the Service Manual for more details. C2155 iBR Water temperature sensor overheat iBR cooling system failure. iBR unit failure Check iBR cooling circuit. Replace iBR unit. Refer to the Service Manual for more details.

C2161 iBR Low voltage detected Battery failure, rectifier failure, damaged circuit wires, battery terminal connection, damaged AC generator or damaged connectors Check fuses 15 (refer to WIRING DIAGRAM). Check ground continuity to the engine block. Refer to the Service Manual for more details. C2200 iS Sensors calibration is corrupted Incompatible firmware or memory failure (Internal memory failure, return to supplier) Defective iS module, replace module and return to supplier. C2210 iS Bridge/CPU temperature sensor overheat Hardware failure or external heat source Check for over utilization/heat. C2220 iS Application calibration is corrupted Incompatible firmware or memory failure (B.U.D.S.

should repair that) Program calibration with B.U.D.S. C2221 iS Application parameters corrupted (backup no. 1 or no. 2) Battery power lost or memory failure (Reset after power-down-up, clear fault. If happens often, verify supply voltage) Check power wiring and fuse. C2222 iS Last session interrupted Unexpected battery power lost Check power wiring and fuse. C2230 iS Internal motor drive failure Motor voltage feedback not fitting with the command Defective iS module, replace module and return to supplier. C2231 iS Motor shorted to ground/battery Current leak detected when the bridge is off Check suspension actuator pump wiring.

C2232 iS Motor open No current while activated Check suspension actuator pump and/or wiring. C2233 iS Motor current software breaker Motor current too high Check suspension actuator pump. C2240 iS Seat position sensor error Open, Shorted to Gnd Sensor not connected Check system circuit at iS module (refer to WIRING DIAGRAM). C2250 iS System current software breaker Battery input current too high Check suspension actuator pump. C2251 iS System disabled and need activation System is locked for safety. Need activation Activate iS using B.U.D.S. activation function.