Bombardier Recreational Products Inc. (BRP) Sea-Doo RXT iS255 GTX LIMITED — Print Preview - C:\DOCUME~1\coderma\LOCALS~1\Temp\.aptcache\smr2009Piranhaen6/tfa03092

Section 03 ELECTRONIC MANAGEMENT SYSTEMS Subsection 04 (MONITORING SYSTEM AND FAULT CODES) 206 smr2009-029 FAULT CODE MODULE DESCRIPTION POSSIBLE CAUSE SERVICE ACTION P062F ECM ECM EEPROM fault - exchange ECM Damaged ECM. Replace ECM. P06B6 ECM ECM Fast ADC fault (knock detection line) P1120 ECM Throttle positions calculated from TPS 1 and TPS 2 not corresponding Damaged throttle actuator, damaged circuit wires, damaged connector or damaged ECM Check system circuit, perform closed throttle with B.U.D.S. Replace throttle actuator, replace ECM.

P1264 ECM Ignition Power stage overload Damaged coil, damaged circuit wires, damaged connector or damaged ECM output pins Fault detected when the engine is running N/A P1502 ECM TOPS functional problem Boat or sensor upside down, damaged circuit wires, damaged connector or damaged ECM output pins Check continuity for circuits A-C4, A-G1, A-F4. Refer to the Service Manual for more details. P1503 ECM TOPS switch short circuit to 12 V Boat or sensor upside down, damaged circuit wires, damaged connector or damaged ECM output pins Check continuity for circuits A-C4, A-G1, A-F4. Refer to the Service Manual for more details.

P1504 ECM TOPS switch short circuit ground Boat or sensor upside down, damaged circuit wires, damaged connector or damaged ECM output pins Check continuity for circuits A-C4, A-G1, A-F4. Refer to the Service Manual for more details. P1505 ECM TOPS switch fault non plausible state Boat or sensor upside down, damaged circuit wires, damaged connector or damaged ECM output pin Check continuity for circuits A-C4, A-G1, A-F4. Refer to the Service Manual for more details. P1506 ECM TOPS switch open circuit Boat or sensor upside down, damaged circuit wires, damaged connector or damaged ECM output pins Check continuity for circuits A-C4, A-G1, A-F4. Refer to the Service Manual for more details.

P1509 ECM N/A N/A N/A P1550 ECM O.T.A.S. sensor voltage not plausible Damaged sensor, damaged circuit wires, damaged connector or damaged ECM Check continuity for circuits B-H3, B-H1 and FB1 -B5. Refer to the Service Manual for more details. P1606 ECM ECM ADC fault - exchange ECM Damaged ECM No service action available for fault P1606.