Bombardier Recreational Products Inc. (BRP) Sea-Doo RXT iS255 GTX LIMITED — Print Preview - C:\DOCUME~1\coderma\LOCALS~1\Temp\.aptcache\smr2009Piranhaen6/tfa03092

Section 03 ELECTRONIC MANAGEMENT SYSTEMS Subsection 04 (MONITORING SYSTEM AND FAULT CODES) 208 smr2009-029 FAULT CODE MODULE DESCRIPTION POSSIBLE CAUSE SERVICE ACTION P1621 ECM Throttle Actuator - Abortion of adaptation Damaged throttle actuator, damaged circuit wires, damaged connector or damaged ECM Check system circuit, perform closed throttle with B.U.D.S. Replace throttle actuator, replace ECM. P1622 ECM Throttle Actuator - Repeated abortion of adaptation Damaged throttle actuator, damaged circuit wires, damaged connector or damaged ECM Check system circuit, perform closed throttle with B.U.D.S. Replace throttle actuator, replace ECM. P1654 ECM Voltage of D.E.S.S.

key switch out of range Damaged D.E.S.S. key switch, damaged circuit wires, damaged connector or damaged ECM output pins Remove D.E.S.S. key and check system circuit B-B2. Refer to the Service Manual for more details. P1657 ECM Electrical fault of D.E.S.S. key communication line Damaged D.E.S.S. key switch, damaged circuit wires, damaged connector or damaged ECM output pins Remove D.E.S.S. key and check system circuit B-B2. Refer to the Service Manual for more details. P1658 ECM Faulty D.E.S.S. key communication Damaged D.E.S.S. key switch, damaged circuit wires, damaged connector or damaged ECM output pins Remove D.E.S.S. key and check system circuit B-B2.

Refer to the Service Manual for more details. P1661 ECM iBR malfunction iBR fault detected by ECM Remove D.E.S.S. key. Perform an electrical system shut down. Clear fault. P1662 ECM iBR torque request is not plausible iBR fault detected by ECM Perform iBR software update if available or replace iBR. P16B6 ECM ECU Fast ADC fault (knock detection line) P16B7 ECM ECU Fast ADC fault (knock detection line) P16B8 ECM ECU Fast ADC fault (knock detection line) P16C0 ECM Fault of ECM ADC P16C1 ECM Fault of ECM ADC P16C2 ECM Fault of ECM monitoring module P16C3 ECM Monitoring fault due to Accelerator Sensor check P16C4 ECM Monitoring fault due to engine speed check