Section 05 ELECTRICAL SYSTEM Subsection 01 (CONTROLLER AREA NETWORK (CAN)) CAN Continuity Tests If a communication problem is present, perform the appropriate continuity test relating to the com- ponent reported by B.U.D.S. Test wire continuity between the corresponding terminal of the CAN bus bar in fuse box no. 2 and the suspected component as follows. Remove cover from fuse box no. 2. The following gives an example between the CAN LO wire and the ECM. NOTE: When working with the ECM, install the ECM ADAPTER TOOL (P/N 529 036 166) on ECM "B" connector. 2009-027-009_a 1. Fuse box no. 1 2. Fuse box no. 2 smr2009-048-001_a EXAMPLE CHECKING ECM CAN LO WIRE Pull out both CAN bus bars.
If continuity is good, CAN lines are functional. If continuity is not good, check wiring, connectors and terminals condition. NOTE: It may be necessary to check the continu- ity to more than one component. Reconnect connectors and reinstall removed parts. smr2009-027-010_d FUSE BOX #2 1. CAN LO bus bar 2. CAN HI bus bar Inspect bus bar condition. Disconnect the connector from the component to be tested. Refer to its appropriate subsection. Use the FLUKE 115 MULTIMETER (P/N 529 035 868) and select . Refer to the CAN BUS DIAGRAM above and read wire resistance between the proper bus bar termi- nal and the component terminal.
Check the con- tinuity of the WHITE/RED wire and the continuity of the WHITE/BLACK wire. smr2009-048 279 ECM CONNECTOR FUSE BOX TERMINAL RESISTANCE B-C2 FB2-C1 Close to 0 (continuity)