Bombardier Recreational Products Inc. (BRP) Sea-Doo RXT iS255 GTX LIMITED — Print Preview - C:\DOCUME~1\coderma\LOCALS~1\Temp\.aptcache\smr2009Piranhaen6/tfa03092

Section 05 ELECTRICAL SYSTEM Subsection 05 (STARTING SYSTEM) Solenoid Dynamic Test Ensure battery and starter solenoid are properly connected. Set ECM in engine drowned mode: Depress throttle lever and install a rubber band to hold lever in full throttle position. Set multimeter to Vdc. Install the D.E.S.S. key. Depress the START/STOP button. As engine is cranking , measure the voltage as per following tables. smr2009-034-010_c 1. Starter motor 2. Starter solenoid If test failed, replace solenoid. If all solenoid dynamic tests are as specified, carry out a STARTER QUICK TEST. Remove rubber band from throttle lever. Reinstall removed parts. Solenoid Removal 1. Disconnect battery.

Refer to CHARGING SYS- TEM section. 2. Detach fuse box 2 from its bracket. 3. Detach diagnostic connector from battery holder. 4. Detach electrical component support from bat- tery holder. 5. Disconnect voltage regulator/rectifier connec- tors. 6. Disconnect starter solenoid connector. smr2009-034-010_a 1. Starter motor 2. Starter solenoid If test failed, check battery and cable from battery to solenoid. If test succeeded, continue with next test. smr2009-034-010_b 1. Starter motor 2. Starter solenoid If test failed, replace solenoid. If test succeeded, continue with next test.

320 smr2009-034 SOLENOID DYNAMIC TEST (ENGINE CRANKING) TEST PROBES VOLTAGE (DC) Solenoid battery post Solenoid starter post 0.2 Vdc max. SOLENOID DYNAMIC TEST (ENGINE CRANKING) TEST PROBES VOLTAGE (DC) Solenoid battery post Battery ground Battery voltage SOLENOID DYNAMIC TEST (ENGINE CRANKING) TEST PROBES VOLTAGE (DC) Solenoid battery post Battery ground Battery voltage