Bombardier Recreational Products Inc. (BRP) Sea-Doo RXT iS255 GTX LIMITED — Print Preview - C:\DOCUME~1\coderma\LOCALS~1\Temp\.aptcache\smr2009Piranhaen6/tfa03092

Section 02 ENGINE Subsection 05 (INTERCOOLER) GENERAL Intercooler Cleaning If temperature in intake manifold is too high or if engine is down in performance, intercooler may require to be cleaned. The exhaust system should be flushed first, as it may unclogged the intercooler. If not, then pro- ceed with the intercooler cleaning procedure as detailed here. NOTE: The exhaust temperature will decrease when the intercooler is clogged because more water is rerouted through the exhaust system. To clean the intercooler, do the following: During assembly/installation, use torque values and service products as in the exploded view. Clean threads before applying a threadlocker.

Re- fer to SELF-LOCKING FASTENERS and LOCTITE APPLICATION at the beginning of this manual for complete procedure. WARNING Torque wrench tightening specifications must be strictly adhered to. Locking devices (e.g.: locking tabs, elastic stop nuts, cotter pins, etc.) must be replaced with new ones. NOTICE Never try to clean the intercooler with chemical products. Only use fresh water. Chemical products will permanently damage the internal parts of intercooler. Hose, cables or locking ties removed during a procedure must be reinstalled as per factory stan- dards. 1. Remove the INTERCOOLER from the water- craft. See procedure further in this section. 2.

Pour fresh water into the water outlet fitting. MAINTENANCE INTERCOOLER FLUSHING Flushing the intercooler with fresh water is essen- tial to neutralize corroding effects of salt or other chemical products present in water. It will help to clean up sand, salt, shells or other particles in in- tercooler. NOTE: Intercooler is flushed with the exhaust system, as they are on the same circuit. Exhaust system and intercooler should be flushed each time: Watercraft is used in salt water and is not ex- pected to be used further the same day. Watercraft is used in foul water. Watercraft is stored for any extended time. Refer to EXHAUST SYSTEM subsection for flush- ing procedure. smr2009-019-008_a 1.

Intercooler water outlet fitting 2. Intercooler water inlet fitting 3. Let water into intercooler for many hours. Oc- casionally, shake the intercooler to soak off de- posits. 4. Rinse the intercooler using a garden hose in- stalled on water outlet. 5. Let water flows out of intercooler a few min- utes to evacuate internal deposits. 6. Check water flow. NOTICE Failure to flush the system, when necessary, will severely damage engine inter- cooler and/or exhaust system. PROCEDURES INTERCOOLER WARNING Let engine cool down prior to work on or near intercooler. 54 smr2009-019 WATER FLOW Low or erratic 1. Repeat cleaning procedure. 2. Replace the intercooler.

High and regular Intercooler is not clogged.