Encoder diagnostics | Diagnosis for encoders with TTL/HTL/HTLs/ interface 8 8.6.3 Counts screen for TTL/HTL/HTLs Figure 39: Counts screen The Counts screen shows the distances of reference marks. The current value is displayed in bold. The list is adapted depending on the direction of rotation. With distance-coded reference marks, the nominal increment is shown in addition to the count values. For this purpose, the display is switched when the first count values have been ascertained and the count values and the nominal increment are shown in one line.
A deviation from the nominal value of the signal period between two reference marks or from the nominal increment indicates a malfunction or improper mounting of the encoder. 100 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024