heidenhain PWT 100, PWT 101 — 8.6.5 PWT display screen for TTL

Encoder diagnostics | Diagnosis for encoders with TTL/HTL/HTLs/ interface 8 Locking function The Switching signals screen includes a locking function. The locking function enables you to lock or release count values. When you open the "Switching signals" screen for the first time, both padlock icons are shown opened. Updating of the count values is enabled. When two valid signal edges are detected, the padlock icon is closed automatically and the display is frozen. You can change the status by tapping the padlock icon. When you tap the padlock icon for the first time, the automatic operation of the locking function is stopped.

Status Function The display of the count values is frozen The count values are no longer updated Updating of the count values is enabled 8.6.5 PWT display screen for TTL 1 2 3 4 5 6 Figure 41: PWT display screen 1 Warning for signal evaluation 2 Bar graphs 3 Reset drag indicator or warning for signal evaluation 4 Count value 5 Reference mark status 6 Status The PWT display screen uses bar graphs to evaluate incremental and reference mark signals of encoders with TTL interface that feature a PWT switchover function. In order to obtain noise-free measurement results, additional signals, e.g., such as homing or limit signals, are deactivated if necessary.