heidenhain PWT 100, PWT 101 — Diagnostic values of the PWT display

8 Encoder diagnostics | Diagnosis for encoders with TTL/HTL/HTLs/ interface Reference mark RM (5) shows the status of reference-mark detection. The product uses the following colors for displaying the status: Color Status Description Blue Reference mark detect- ed The display is activated for approx. 0.5 s. If the reference marks follow in too quick a succession, the display may seem to be continuously active. Gray Reference mark not detected Reference mark not yet traversed or reference mark not detected If the reference mark is not detected correctly during signal evaluation, a signal evaluation warning is additionally displayed next to the RM.Pos. (reference mark position) and RM.ZC.

(reference-mark zero crossovers) bar graphs. Tapping the display opens the Display options for count value screen. Status The Status display (6) shows whether there are any messages about the connected encoder. Green: There are no messages Red: There are messages Tapping the display opens the Encoder status screen. Further information: "Encoder status screen ", Page 95 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024 107