Encoder diagnostics | Various diagnostics screens 8 8.1 Various diagnostics screens The product provides the following options for encoder diagnostics: If the Automatic Diagnosis menu is used, the product tries to automatically identify the encoder interface and run the appropriate diagnosis. Further information: "Performing Automatic Diagnosis", Page 59 The Manual Diagnosis menu enables you to manually set the encoder interface (for example, if the product does not automatically identify the encoder interface). Further information: "Performing Manual Diagnosis", Page 60 In both cases the device shows different views during the diagnosis, depending on the encoder interface.
The screens automatically adapt to the respective encoder function. The screens available in each case are shown in the following chart. Automatic Diagnosis Manual Diagnosis Manual diagnostics settings Serial, EnDat 2.2, EnDat 3, EnDat + 1 Vpp, EnDat + TTL, EnDat + HTL *1 DRIVE-CLiQ TTL 1 Vpp, 11 µApp, 1 Vpp + Z1 HTL, HTLs ( *1 only via Manual Diagnosis ) The designation "serial" refers to the following interfaces: Fanuc Mitsubishi Panasonic Yaskawa If the Automatic Diagnosis does not identify an encoder correctly, you have to connect the encoder via the Manual Diagnosis menu.
In the Manual Diagnosis menu, you can select the EnDat 2.2 interface separately to communicate specifically via EnDat 2.2 on encoders with EnDat 3 interface (ordering designation E30-RM). 58 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024 Online diagnostics Temperature Encoder information Position 1/2 Position Position 2/2 PWT display (1 Vpp) Level display (TTL, HTL) PWT display Level display Sine commutation Encoder information Counts Switching signals PWT display